TIGO TS4 Rapid Shutdown Units - What are the Differences?
8,274
Published 2023-09-13
signaturesolar.com/search.php?search_query=tigo&se…
--------------------------------------------------------
Join us as Kelly discusses the differences between the TIGO Rapid Shutdown units, the TS4-A-O, TS4-A-S, TS4-A-F, and TS4-A-2F. She will discuss which components may be best suited for your PV system and why.
--------------------------------------------------------
TIGO Optimizer Shading Test
• Exploring the Functionality of Tigo O...
Check out the TIGO TS4 - Inverter Compatibility list below:
www.tigoenergy.com/inverter-compatibility
--------------------------------------------------------
TS4-A-O:
signaturesolar.com/tigo-ts4-a-o-optimizer-rapid-sh…
TS4-A-S:
signaturesolar.com/tigo-15a-700w-1500v-ul-1000v-ie…
TS4-A-F:
signaturesolar.com/tigo-ts4-a-f-rapid-shutdown-15a…
TS4-A-2F:
signaturesolar.com/tigo-15a-1000w-1500vul-1000viec…
--------------------------------------------------------
Recommended Solar Panels:
signaturesolar.com/shop-all/solar-panels/
Solar Panel Mounting Hardware:
signaturesolar.com/shop-all/solar-panel-racking/
--------------------------------------------------------------
Recommended Solar Batteries:
EG4-LL: signaturesolar.com/shop-all/batteries/eg4-ll/
EG4 Lifepower4: signaturesolar.com/shop-all/batteries/eg4-lifepowe…
EG4 PowerPro: signaturesolar.com/shop-all/batteries/eg4-powerpro…
--------------------------------------------------------------
Recommended Solar Inverters:
EG4 18KPV Hybrid Inverter | All-In-One Solar Inverter | 18000W PV Input | 12000W Output | 48V 120/240V
signaturesolar.com/eg4-18kpv-hybrid-inverter-all-i…
3kW Off-Grid - EG4 3000EHV-48
signaturesolar.com/eg4-3kw-off-grid-inverter-3000e…
- Features: 3000W Output | 5000W PV Input | 500 VOC Input
--------------------------------------------------------------
Shop Kits & Bundles: signaturesolar.com/kits-bundles/
Need additional wiring or system components for your DIY Solar Project?
signaturesolar.com/shop-all/system-components/
signaturesolar.com/shop-all/system-components/wiri…
All Comments (16)
-
This described for me what I needed, and what Tigo's own info could not. Great!
-
Nicely done. I'm still learning about solar systems and this is an important area that I was not aware of. Thank you for the demonstration.
-
Great description! Thanks for making this and other videos!
-
Good information, very helpful. Thank you for this.
-
Very good info !
-
Absolutely incredible explanation. Thank you so much
-
Thanks for sharing this
-
very well done, thank you.
-
Thanks !
-
sad, that there is no device for Optimization AND Fire Shutdown AND Monitoring. Yes, you can combine them, but who wants to clip 2 modules behind the pv modules with all the risks of defects (and of course the price when using many pv modules). So the m device can really NOT separate the module from the string by command?
-
Hi I’m about to order 6 O versions, will they work without the tap ? Or are they going to need a firmware update? Many thanks
-
Thank you for sharing I have a question since I'm in ground Mount therefore I don't need these however I do like the idea of being able to optimize having said that I will have a high voltage array with eight panels 480 watts each combined with a Schneider Electric 100 amp 600 volt charge controller what will you recommend for me and how many of these would I need thank you
-
Excellent results from TS4 here. Optimisation is giving me the edge in a shaded array. Recomended if any shading I have 20 of them.
-
Safety looks expensive. Do I need to add this type of system to remote ground and none occupied structures?
-
how long are the cables